ORIGINAL PAPER
Quantification of heat balance for windows with varying numbers of window panes and geographical exposure in the climate of the Wielkopolska region
,
 
 
 
More details
Hide details
1
Poznań University of Life Sciences, Institute of Biosystem Engineering ul. Wojska Polskiego 28, 60-637 Poznań, Poland
 
 
Journal of Research and Applications in Agricultural Engineering 2018;63(4):31-37
 
KEYWORDS
ABSTRACT
The paper presents results of simulation tests for the heat balance of double, triple and quadruple glazed windows with eastern, southern, western and northern exposure, conducted for the climate conditions of the city of Poznań and the Wielkopolska region in response to the needs of eco power engineering. It was shown that in the summer period a greater number of window panes and a change in exposure from southern to eastern, western and northern result in a considerable reduction of heat balance for these windows. In the summer months from May to August heat balance of windows with eastern, southern and western exposure is comparable. The heat balance of windows with the northern exposure is much lower in each month of the summer period. In the winter period the highest and positive heat balance is recorded for windows with the southern exposure. Windows facing the other geographical directions have a comparable balance with values around zero. At all the exposures an increased number of window panes to a relatively limited extent improves heat balance, in general for the entire winter period and in its individual months.
REFERENCES (15)
1.
Yang L, Lam JC, Liu J, Tsang CL.: Building energy simulation using multi-years and typical meteorological years in different climates. Energy Conversion and Management, 2008, 49, 113-124.
 
2.
Collins L., Natarajan S., Levermore G.: Climate change and future energy consumption in UK housing stock. Building Services Engineering Research and Technology, 2010, 31, 75-90.
 
3.
Grudzińska M.: Climatic Zones in Poland and the Demand for Heating in a Typical Residential Building. “Book of extended abstracts”. Paper presented at the conference: SBE16 Hamburg, Strategies, Stakeholders, Success factors, 7th – 11 th March 2016.
 
4.
Grudzińska M., Jakusik E.: The efficiency of a typical meteorological year and actual climatic data in the analysis of energy demand in buildings. Building Services Engineering Research and Technology, 2015, 36/6, 658-669. SAGE Publications Ltd. DOI: 10.1177/0143624415573454.
 
5.
Grudzińska M.: Dane klimatyczne a zapotrzebowanie na energię w pomieszczeniach mieszkalnych o różnej konstrukcji. Przegląd budowlany, 2014, 10, 20-24.
 
6.
Grudzińska M.: Konstrukcja okien a bilans cieplny pomieszczenia. Przegląd budowlany, 2011, 7-8, 56-59.
 
7.
Grudzińska M.: Wielkość okien a bilans cieplny pomieszczenia. Przegląd budowlany, 2011, 10, 32-35.
 
8.
Starkiewicz A.A.: Bilans cieplny stolarki okiennej. Izolacje, 1, 2012, 73-77.
 
9.
Rozporządzenie Ministra Infrastruktury i Rozwoju z dnia 27 lutego 2015 r. w sprawie metodologii wyznaczania charakterystyki energetycznej budynku lub części budynku oraz świadectw charakterystyki energetycznej.
 
10.
Wskaźniki emisji i wartości opałowe paliwa oraz typowe lata meteorologiczne i statystyczne dane klimatyczne do obliczeń energetycznych budynków. http://mib.gov.pl/2-Wskazniki_.... Dz. U. 2013 poz. 926.
 
11.
Dz. U. 2013 poz. 926. Rozporządzenie Ministra Transportu, Budownictwa i Gospodarki Morskiej z dnia 5 lipca 2013 r. zmieniające rozporządzenie w sprawie warunków technicznych, jakim powinny odpowiadać budynki i ich usytuowanie.
 
12.
Standards:.
 
13.
PN-EN 12831: 2006. „Instalacje ogrzewcze w budynkach. Metoda obliczania projektowego obciążenia cieplnego”.
 
14.
PN-EN ISO 13790:2009. „Energetyczne właściwości użytkowe budynków. Obliczanie zużycia energii na potrzeby ogrzewania i chłodzenia”.
 
15.
PN-EN ISO 10077-1:2017-10. Cieplne właściwości użytkowe okien, drzwi i żaluzji. Obliczanie współczynnika przenikania ciepła.
 