ORIGINAL PAPER
The identification of selected window energy parameters in winter and summer periods in the Greater Poland region
More details
Hide details
1
Uniwersytet Przyrodniczy w Poznaniu, Instytut Inżynierii Biosystemów ul. Wojska Polskiego 28, 60-637 Poznań, Poland
Journal of Research and Applications in Agricultural Engineering 2018;63(1):8-12
KEYWORDS
ABSTRACT
The simulation research results of gains, losses and heat balance of two-, three- and four-paned windows positioned at 30, 60 and 90° angles relative to a surface for climatic conditions in Poznań and the Greater Poland region expected in the eco-power industry have been presented. It has been shown that in a summer period the increase in a number of panes and the angle of widows decreases high solar heat gain which determines similar alternations of heat balance at low losses. Particularly high window heat balance occurs from May to August due to high sun exposure at low heat losses. In winter, window heat balance is generally positive, apart from December, when it is minor and negative due to the lowest solar radiation at not the lowest outdoor temperature. Increasing a number of panes and a window angle does not change significantly window heat balance in a winter period.
REFERENCES (16)
1.
Chow D., Levermore G.J.: The effects of future climate change on heating and cooling demands in office buildings in the UK. Building Services Engineering Research and Technology, 2010, 31, 307-323.
2.
Yang L., Lam J.C., Liu J., Tsang C.L.: Building energy simulation using multi-years and typical meteorological years in different climates. Energy Conversion and Management, 2008, 49, 113-124.
3.
Collins L., Natarajan S., Levermore G.: Climate change and future energy consumption in UK housing stock. Building Services Engineering Research and Technology, 2010, 31, 75-90.
4.
Grudzińska M.: Climatic Zones in Poland and the Demand for Heating in a Typical Residential Building. “Book of extended abstracts”. Paper presented at the conference: SBE16 Hamburg, Strategies, Stakeholders, Success factors, 7 – 11 th March 2016.
5.
Grudzińska M., Jakusik E.: The efficiency of a typical meteorological year and actual climatic data in the analysis of energy demand in buildings. Building Services Engineering Research and Technology, 2015, 36/6, 658-669. SAGE Publications Ltd. DOI: 10.1177/0143624415573454.
6.
Grudzińska M.: Dane klimatyczne a zapotrzebowanie na energię w pomieszczeniach mieszkalnych o różnej konstrukcji. Przegląd budowlany, 2014, 10, 20-24.
7.
Grudzińska M.: Konstrukcja okien a bilans cieplny pomieszczenia. Przegląd budowlany, 2011, 7-8, 56-59.
8.
Grudzińska M.: Wielkość okien a bilans cieplny pomieszczenia. Przegląd budowlany, 2011, 10, 32-35.
9.
Starkiewicz A.A.: Bilans cieplny stolarki okiennej. Izolacje, 1, 2012, 73-77.
10.
Rozporządzenie Ministra Infrastruktury i Rozwoju z dnia 27 lutego 2015 r. w sprawie metodologii wyznaczania charakterystyki energetycznej budynku lub części budynku oraz świadectw charakterystyki energetycznej.
11.
Wskaźniki emisji i wartości opałowe paliwa oraz typowe lata meteorologiczne i statystyczne dane klimatyczne do obliczeń energetycznych budynków.
http://mib.gov.pl/2-Wskazniki_....
12.
Dz. U. 2013 poz. 926. Rozporządzenie Ministra Transportu, Budownictwa i Gospodarki Morskiej z dnia 5 lipca 2013 r. zmieniające rozporządzenie w sprawie warunków technicznych, jakim powinny odpowiadać budynki i ich usytuowanie.
14.
PN-EN 12831: 2006. Instalacje ogrzewcze w budynkach. Metoda obliczania projektowego obciążenia cieplnego.
15.
PN-EN ISO 13790: 2009. Energetyczne właściwości użytkowe budynków. Obliczanie zużycia energii na potrzeby ogrzewania i chłodzenia.
16.
PN-EN ISO 10077-1: 2017-10. Cieplne właściwości użytkowe okien, drzwi i żaluzji. Obliczanie współczynnika przenikania ciepła.